TitleProduct

Liquid Chromatography (equivalent degrees system)

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Hunan

  • Validity to:

    Long-term effective

  • Last update:

    2017-10-25 20:00

  • Browse the number:

    195

Send an inquiries

Company Profile

Labmen Instrument Limited

By certification [File Integrity]

Contact:Mr. David(Mr.)  

Email:

Telephone:

Area:Hunan

Address:Hunan

Website: http://labmen1998.nbshuangheng.com/

Product Details


Technical parameters:
Max working pressure: 42MPa (0.001-10mL/min);Flow range: (0.001-10ml/min) regulating every 0.0001ml/min;
High-efficiency liquid constant-current pump&colon; Ss <0&period;2&percnt;&comma; Sr <0&period;1&percnt;&semi;Flow accuracy&colon;
Set accuracy ± 2&percnt;&comma; within the flow rate of 2-5&percnt;&comma; methanol &sol; water volume ratio of 80&colon;20 
Flow accuracy&colon; RSD <0&period;5&percnt; &lpar;1mL&sol;min&rpar; 
Flow stability&colon; RSD <0&period;1&percnt; UV3000 UV detector&colon; 
Noise <20uAU&semi; drifting <80uAU 
Spectral Bandwidth&colon; 6nm&semi; optical path&colon; 10mm 
Wavelength range&colon; 170nm-620nm &lpar;deuterium lamp&rpar;&comma; 170nm-800nm &lpar;deuterium lamps plus tungsten lamp&rpar; 
Lamp source&colon; deuterium lamp &lpar;standard configuration&rpar;&semi; tungsten lamp &lpar;replaceable&rpar; 
Wavelength accuracy&colon; ± 2nm 
Wavelength repeatability&colon; 0&period;2nm
Scanning&colon; stop scanning&comma; programmable scan&comma; namely&comma; starting and ending point of the scan can be set
Scanning steps can be set 
Detection range&colon; 0-2AU Baseline noise&colon;≤ 2&period;0X10-4AU &sol; h dynamic&comma; flow rate&colon; 1ml&sol;min&comma; methanol &sol; water &equals; 80&colon;20 
Wavelength&colon; 254 Baseline drifting&colon; ≤ 1&period;5X10-4AU &sol; h dynamic&comma; flow rate 1ml&sol;min&comma; methanol &sol; water &equals; 80&colon;20
Wavelength&colon; 254 
Time constant 0&period;1&sol;0&period;2&sol;0&period;5&sol;1&sol;2&sol;5&sol;10s 
Automatic zeroing&comma; full scale&comma; Min&period; test line&colon; 0&period;4 × 10-8g&sol;ml Workstation&colon; Chromatographic working software
 
Main Features and Correlation Parameter&colon;
High pressure analyses&sol;semi-preparation pump
Perfusion way&colon; Double-piston Pump&comma; double plunger imbibing&verbar;
Displaying&colon; the large LCD with 320X240 displays&comma; blue backlight
System security&colon; startup and stop in a low speed&comma; free adjustment for the highest and the lowest pressure&comma; automatically store the user's data&period; 
System connection&colon; 1&sol;8" pipeline connection 
Control&colon; Independent-- control model&comma; through the front panel buttons to set all the parameters&period; When work under the high-pressure gradient model&comma; there is a pump function as the main pump to control other high pressure pumps in the same type and can also test and verify the gradient mode through the gradient profiles on the screen&period;
Common mode&colon; Though RS232 to control the high pressure pumps&period;
Electrical source&colon; 220V±10&percnt;&comma; 50Hz&comma; 400WUV&sol;VIS detector
Control&colon; Independent-- control model&comma; through the front panel buttons to set all the parameters&period;
Common mode&colon; Control the high pressure pumps Though RS232&period;
Display&colon; The large LCD with 320X240 displays&comma; the blue backlight can be adjusted&period; 
Electrical source power&colon; 220V±10&percnt;&comma; 50Hz&comma; 60W
Size and weight&colon; 398X149X267mm &lpar;depth X height X width&rpar;&comma; 14kg
GLP information&colon; the overall time of the lamps&comma; frequencies of the electric lights&comma; the number of replacing lights and the serial number of the product and so on&period;
 
Liquid Chromatography &lpar;equivalent degrees system&rpar;
Max working pressure 42MPa
Flow range &lpar;0&period;001-10ml&sol;min&rpar; regulating every 0&period;0001ml&sol;min
Set accuracy ± 2&percnt;
Flow accuracy RSD <0&period;5&percnt; &lpar;1mL&sol;min&rpar; 
Flow stability RSD <0&period;1&percnt;
Noise <20uAU
drifting <80uAU
Spectral Bandwidth 6nm
 
Contact&colon;